Skip to content
  • There are no suggestions because the search field is empty.

How do I perform a refresh on a Riegl RBNE 2210 battery?

RIEGL RBNE 2210 Battery Refresh Procedure

Purpose

Refreshing the battery helps maintain battery performance and capacity.

Instructions

  1. Attach the battery to the scanner.
  2. Connect the scanner to mains power:
    • Plug the mains lead into Power Port 1 or Power Port 2 on the scanner.
    • Do not connect the mains lead to the battery charging port.
  3. Switch on the scanner.
  4. On the touchscreen, press the Battery icon. (If you are using a VZ-400, navigate to Settings > Peripherals > Rechargeable Battery...)
  5. From the battery menu, select Refresh. (On the VZ-400, find the Refresh Cycles field)
  6. Choose the number of refresh cycles:
    • 1 cycle – acceptable
    • 2 cycles – recommended
    • 3 cycles – ideal
  7. Press OK to start the refresh process.
  8. Leave the scanner connected to mains power until the refresh process is complete.

Duration

  • 3 refresh cycles typically take approximately 16–18 hours.

Important Notes

  • The battery must remain attached to the scanner throughout the refresh process.
  • Ensure a continuous mains power supply is maintained during the entire refresh cycle.
  • Do not disconnect the battery or power supply until the refresh is complete.